Home > Product > Roll Up Door > Fire Rated Steel Roll Up Door

Fire Rated Steel Roll Up Door

Plan a steel rolling fire shutter as part of the building fire-compartment strategy. Curtain, guides, closing controls and supporting construction need to be matched to the required test evidence and project approval.

Send YUOU your opening dimensions, required rating and test standard, wall construction, alarm interface and approval requirements for a configuration-based quotation. Review the selected equipment and installation requirements before confirming the order.

Technical Data

Door Panel Material Steel + Aluminosilicate rock wool
Frame Material Galvanized steel
Max Size(mm) Width * Height 8000mm*10000mm
Power Supply 3phase 380v±10% 50Hz,DC24V Controller
Opening and Closing Speed 5-7.5m/min
Wind Resistance 28-35m/s (Class 10-12)
Air Tightness Leakage through the door is 95m³/hour under 30 pa pressure
Unexposed Surface Temperature ≤154℃
Smoke Leakage ≤0.12M³/(SQM/MIN)

Options

Voltage Standard: 3phase 380v±10%. Other voltages can be customized.
Color White/Grey.etc Other colors can be customized.
Other Fire-Fighting Devices ①Smoke Detector ②Heat Detector ③Smoke Barrier Wall

Product Details

Use the following product details to compare suppliers against the same project requirements. YUOU can review these items with your drawings before the final configuration and quotation are confirmed.

Structure Diagram

Use the structure drawing to review the fire rated steel roll up door assembly, installation interfaces and available clearances.

Send opening dimensions, required rating and test standard, wall construction, alarm interface and approval requirements. Confirm the selected configuration on the project drawing before manufacture.

Steel fire rated roller shutter doors
steel fireproof rooler door slats

Door Slats

The steel fire-shutter curtain is selected around the opening dimensions, required closure and working environment.

Confirm the material, thickness or profile, finish and any optional infill in the quotation. Match the selected construction to the drive, guides and installation drawing rather than treating all options as interchangeable.

Fireproof Motor

The drive for the fire rated steel roll up door must suit the moving weight, transmission and expected operating duty.

Confirm torque, power supply, mounting, limits and manual operation for the selected configuration. Controller and sensor compatibility should be checked before installation.

fire roller shutter door motor
Limit controller

Electronic Limiters and Remote Control

Limit controls establish the intended open and closed positions for the selected operator. Remote operation can be included where the control system supports it.

Confirm signal compatibility, access control and obstacle protection. Set and test the limits as part of commissioning rather than relying on factory settings alone.

Track and Reset Wheel

The guides and rollers keep the fire rated steel roll up door aligned through its travel. Their dimensions and fixings need to suit the curtain or panel assembly and operating loads.

Review support strength, clearances, alignment and access for adjustment. Confirm the selected sealing inserts and maintenance requirements on the installation drawing.

fire rated roller door track
steel fireproof roll up door hood cover

Hood Cover

The hood encloses the rolling assembly and gives access points a finished appearance while helping limit dust and debris exposure.

Check cover dimensions, weather exposure, guarding and service access against the installation space. Do not remove guarding solely to reduce headroom without reviewing the arrangement.

Why Specify a YUOU Fire Rated Steel Roll Up Door?

Compare the configuration, not just the price: match these details to your opening and daily workflow.

Steel Rolling Assembly

The steel curtain and guides form the specified shutter assembly, not a collection of interchangeable parts.

Coordinated Closure

The motor and fire-control sequence should be matched to the alarm design and intended closing behavior.

Compact Opening Layout

A rolling arrangement can suit wide compartment openings where hinged leaves are impractical.

Defined Interfaces

Confirm guides, brackets, hood and structural fixings against the surrounding construction.

Documented Selection

Request evidence applicable to the selected size, assembly and required rating.

Inspection Planning

Provide access for periodic inspection, testing and maintenance of the closure system.

Fire Rated Steel Roll Up Door FAQ

No. Fire performance applies to a tested assembly and its permitted installation. A standard steel shutter is not a substitute.

No. Confirm the required standard, rating, permitted dimensions and supporting test or certification documents for the quoted assembly.

Do not assume it can. Escape arrangements and any adjacent personnel door must be reviewed against the building fire and egress design.

Provide the fire strategy, signal type, closing sequence, power-loss behavior and reset requirements for review by the project team.

Send opening dimensions, required rating and test standard, wall construction, alarm interface and approval requirements. Include drawings or site photos where available so the configuration, installation scope and required options can be confirmed.

Inside YUOU Manufacturing

View the production environment and manufacturing work shown in the YUOU factory video. Confirm the production, inspection and supply scope for your project in the quotation.

Related Products

Request a Quote for Your Project

Share the products, approximate sizes and quantities you need. We will review your requirements and confirm quotation details with you.

Not sure about the specifications? Send the details you have.

Your Quote Request

One product or a mixed order - share your requirements below.

PDF, JPG, PNG or XLSX. Up to 3 files, 5 MB each.

Get A Free Quote

Fill out the form below, and we will be in touch shortly.

Your Quote Request

One product or a mixed order - share your requirements below.

PDF, JPG, PNG or XLSX. Up to 3 files, 5 MB each.